中文 / English

AC-DC Converter Application Guidelines

时间:2016-01-13 10:48     点击:

1. Foreword
The following guidelines should be carefully read prior to converter use. Improper use may
result in the risk of electric shock, damaging the converter, or fire.
1.1 Caution
  1. Converter should be handled with care to avoid causing damage to the product by impact or fall.
  2. Do not open the case or touch internal components, which could cause damage to the products by electrostatic or other reasons.
  3. Do not approach or touch the heat sink or the case when the converter is in operation to avoid injury to our body by abnormal operating.
1.2 Notice:
a. Please make sure that all the input、output  terminals, signal pin and necessary peripheral components are properly connected according to the instruction. 
 
b. The series of converter belongs to primary power, should be used in compliance with certain safety standards.
 
c. In order to meet safety standard requirements, install a slow blow fuse at input of converter.
 
d. Converter input stage is hazardous energy that it should be out of reach from the end user. Product manufacturer should also make sure that the input、output of converter is protected from being shorted from any service engineer or any metal parts left.
 
e. The application circuits and parameters shown are for reference only. All parameters
and circuits are to be verified before completing the circuit design.
 
f. Clients are advised to unload aging 1 hour every six month when the converter is kept in stock or isn’t used for more than half a year to keep its long life and good reliability.
 
g. It’s normal when there is slight noise inside the converter while its operated with light or no load.
 
h. We can’t keep every customer well informed about changes herein, please pay more attention to our latest information, for other questions, please refer to our AC-DC Converter General Failure Analysis.
 
i. Converter is component,it requires designed and guidance by professionals during installation and usage.
 
 
二、Type Selection Guidance
First determine to use standard or customized converter by the specification of the converter in accordance with the required standard.
Figure 1 is the AC DC type selection diagram
Example : YAW  05   S  05  
         ①  ②  ③  ④         
① Model NO
② Output Watt
③ S : Single output, D : Dual output, T : Triple output,
④ Output voltage
Typical input voltage range : 85 to 265Vac or 165 to 265Vac
 
Fig.1 Selection Diagram 
 
DIP                                 SIP
Note: Due to the development of company and technology innovation,new product release could lead to the update of the diagram.
Step one: define the type of input type.
Define the type of input source is AC or DC; choose AC/DC converter if it’s AC while choose DC/DC if it’s DC.
Step two: choose the standard reference voltage according to input voltage. See Fig.1 input voltage range.
Step three: choose product power and package type according to load-magnitude. We have single inline SIP package, double inline small DIP package, common horizontal package, small horizontal package and DIN rail package. Moreover, we have R&D open frame for YAWN series of products.
Step four: choose output voltage according to the load type. Our product output typically are 3.3V, 5V, 9V, 12V, 15V, 24V, ±5V,±12V,±15V.
Step five: choose isolation type.
Isolation property, which makes the input and output of converter are separate power. In industry bus system, it can isolate from harsh environment, and eliminate ground loop. In mixed circuit, it realize noise isolation of sensitive analog circuit and digital circuit. It realizes voltage converter in multi-voltage power supply system. Our  AC-DC isolation power are 2500VAC, 3000VAC and 4000VAC.
 
In general, try to use the standard power module, which could meet the requirement of low cost, mature technology, reducing resistance of development, saving development time. For high isolation, ultra wide voltage range, hot environment, EMC certification and other special requirements please refer to the service man.
 
Yaohua power technology Co.,ltd